An analytical assay has been developed and validated for ultrafast and high-throughput mass spectrometric determination of pemetrexed concentrations in plasma using matrix assisted laser desorption/ionization-triple quadrupole-tandem mass spectrometry. Patient plasma samples spiked with the internal
Purpose: Carboplatin area under the curve (AUC) 5 ml/min on day 1 with gemcitabine 1,250 mg/m2on day 1 and day 8 is a widely used regimen in advanced non-small cell lung cancer. Grade 3-4 thrombocytopenia and neutropenia are frequent. The aim of this study is to investigate whether toxicity of gemci
Purpose: To estimate the performance of digital chest radiography for detection of lung cancer. Materials and Methods: The study had ethics committee approval, and a nested case-control design was used and included 55 patients with lung cancer detected at computed tomography (CT) and confirmed with
Purpose: To compare manual measurements of diameter, volume, and mass of pulmonary ground-glass nodules (GGNs) to establish which method is best for identifying malignant GGNs by determining change across time. Materials and Methods: In this ethics committee - approved retrospective study, baseline
Purpose: To compare manual measurements of diameter, volume, and mass of pulmonary ground-glass nodules (GGNs) to establish which method is best for identifying malignant GGNs by determining change across time. Materials and Methods: In this ethics committee - approved retrospective study, baseline
Objective: To assess volumetric measurement variability in pulmonary nodules detected at low-dose chest CT with three reconstruction settings. Methods: The volume of 200 solid pulmonary nodules was measured three times using commercially available semi-automated software of low-dose chest CT data-se
Background: In lung cancer CT screening, participants often have an indeterminate screening result at baseline requiring a follow-up CT. In subjects with either an indeterminate or a negative result after screening, we investigated whether health-related quality of life (HRQoL) changed over time and
BACKGROUND: The use of multidetector computed tomography (CT) in lung-cancer screening trials involving subjects with an increased risk of lung cancer has highlighted the problem for the clinician of deciding on the best course of action when noncalcified pulmonary nodules are detected by CT. METHOD
BACKGROUND. Computed tomography (CT) screening is an important new tool for the early detection of lung cancer. In the current study, the authors assessed the discomfort associated with CT scanning and the subsequent wait for results and health-related quality of life (HRQoL) over time. METHODS. A t