Person
As a consequence of improved technology, there is growing clinical interest in the use of multi-detector row computed tomography (MDCT) for non-invasive coronary angiography. Indeed, the accuracy of MDCT to detect or exclude coronary artery stenoses has been high in many published studies. This repo
AIMS: To study recovery of segmental wall thickening (SWT), ejection fraction (EF), and end-systolic volume (ESV) after acute myocardial infarction (AMI) in patients who underwent primary stenting with drug-eluting stents. Additionally, to evaluate the predictive value of magnetic resonance imaging
OBJECTIVE: To compare clinical outcome of paclitaxel eluting stents (PES) versus sirolimus eluting stents (SES) for the treatment of acute ST elevation myocardial infarction. DESIGN AND PATIENTS: The first 136 consecutive patients treated exclusively with PES in the setting of primary percutaneous c
OBJECTIVES: To determine the long term outcome after intracoronary beta radiation therapy (IRT). SETTING: Tertiary referral centre. METHODS: The rate of major adverse cardiac events (MACE) was retrospectively determined in 301 consecutive patients who were treated with IRT. MACE was defined as death
Long-length stenting has a poor outcome when bare metal stents are used. The safety and efficacy of the sirolimus-eluting stent (SES) in long lesions has not been evaluated. Therefore, the aim of the present study was to evaluate the clinical and angiographic outcomes of SES implantation over a very
BACKGROUND: The factors associated with the occurrence of restenosis after sirolimus-eluting stent (SES) implantation in complex cases are currently unknown. METHODS AND RESULTS: A cohort of consecutive complex patients treated with SES implantation was selected according to the following criteria:
Intracoronary ultrasound (ICUS) is often used in studies evaluating new interventional techniques. It is important that quantitative measurements performed with various ICUS imaging equipment and materials are comparable. During evaluation of quantitative coronary ultrasound (QCU) software, it appea
AIMS: The aim of this study is to compare the efficacy of sirolimus-eluting stents (SES) on neointimal growth and vessel remodelling for in-stent restenosis versus de novo coronary artery lesions using serial intravascular ultrasound (IVUS). METHODS AND RESULTS: The study population consisted of 86
AIMS: To investigate the effect on risk of major adverse cardiac events (MACE) of lipid lowering treatment with fluvastatin 80 mg/day after a first percutaneous coronary intervention in patients with stable and unstable angina. METHOD AND RESULTS: This prespecified subgroup analysis of the LIPS (Les
Go to page top
Go back to contents
Go back to site navigation