KNAW

Publication

Accurate Quantification of Microorganisms in PCR-Inhibiting... (2009) Open access

Pagina-navigatie:
Title Accurate Quantification of Microorganisms in PCR-Inhibiting Environmental DNA Extracts by a Novel Internal Amplification Control Approach Using Biotrove OpenArrays
Published in Applied and Environmental Microbiology, Vol. 75, No. 22, p.7253-7260. ISSN 0099-2240.
Author Doorn, van R.; Klerks, M.M.; Gent-Pelzer, van M.P.E.; Speksnijder, A.; Kowalchuk, G.A.; Schoen, C.D.
Date 2009
Reference(s) Biointeracties en plantgezondheid / Biointeractions and Plant Health, Biointeracties en plantgezondheid / Biointeractions and Plant Health
Language English
Type Article
Abstract PCR-based detection assays are prone to inhibition by substances present in environmental samples, thereby potentially leading to inaccurate target quantification or false-negative results. Internal amplification controls (IACs) have been developed to help alleviate this problem but are generally applied in a single concentration, thereby yielding less-than-optimal results across the wide range of microbial gene target concentrations possible in environmental samples (J. Hoorfar, B. Malorny, A. Abdulmawjood, N. Cook, M. Wagner, and P. Fach, J. Clin. Microbiol. 42: 1863-1868, 2004). Increasing the number of IACs for each quantitative PCR (qPCR) sample individually, however, typically reduces sensitivity and, more importantly, the reliability of quantification. Fortunately, current advances in high-throughput qPCR platforms offer the possibility of multiple reactions for a single sample simultaneously, thereby allowing the implementation of more than one IAC concentration per sample. Here, we describe the development of a novel IAC approach that is specifically designed for the state-of-the-art Biotrove OpenArray platform. Different IAC targets were applied at a range of concentrations, yielding a calibration IAC curve for each individual DNA sample. The developed IACs were optimized, tested, and validated by using more than 5,000 unique qPCR amplifications, allowing accurate quantification of microorganisms when applied to soil DNA extracts containing various levels of PCR-inhibiting compounds. To our knowledge, this is the first study using a suite of IACs at different target concentrations to monitor PCR inhibition across a wide target range, thereby allowing reliable and accurate quantification of microorganisms in PCR-inhibiting DNA extracts. The developed IAC is ideally suited for high-throughput screenings of, for example, ecological and agricultural samples on next-generation qPCR platforms.
Publication http://library.wur.nl/WebQuery/wurpubs/395288
Persistent Identifier urn:nbn:nl:ui:32-395288
Metadata XML
Repository Wageningen University & Research Centre

Go to page top
Go back to contents
Go back to site navigation